一、塑料管浮子流量计基本参数
长 管 型(无导杆)
|
短 管 型(均有导杆)
|
||||
型号S
|
长度mm
|
规 格
|
型号S
|
长度mm
|
规 格
|
LZB-15
|
280
|
2-20L/h
|
LZB-15
|
200
|
5-50L/h
|
3-30L/h
|
6-60 L/h
|
||||
4-40L/h
|
10-100 L/h
|
||||
6-60L/h
|
16-160 L/h
|
||||
10-100 L/h
|
25-250 L/h
|
||||
16-160 L/h
|
40-400 L/h
|
||||
25-250 L/h
|
60-600 L/h
|
||||
40-400 L/h
|
100-1000 L/h
|
||||
50-500 L/h
|
LZB-25
|
230
|
100-1000 L/h
|
||
60-600 L/h
|
160-1600 L/h
|
||||
100-1000L/h
|
250-2500 L/h
|
||||
LZB-25
|
380
|
100-1000 L/h
|
300-3000 L/h
|
||
160-1600 L/h
|
LZB-32
|
288
|
400-4000L/h
|
||
250-2500 L/h
|
600-6000L/h
|
||||
300-3000 L/h
|
LZB-50
|
341
|
0.4-4m3/h
|
||
LZB-50
|
435
|
0.4-4m3/h
|
0.6-6 m3/h
|
||
0.6-6 m3/h
|
1-10 m3/h
|
||||
1-10 m3/h
|
1.6-16 m3/h
|
||||
1.6-16 m3/h
|
LZB-65
|
430
|
3-16m3/h
|
||
有导杆
|
5-25m3/h
|
||||
LZB-100
法兰 带导杆 |
555
|
10-50 m3/h
|
8-40m3/h
|
||
10-60 m3/h
|
12-60m3/h
|
||||
14-90 m3/h
|
LZB-80
法兰 |
|
3-16 m3/h
|
||
LZB-125
带导杆 |
555
|
18-150 m3/h
|
5-25 m3/h
|
||
18-120 m3/h
|
8-40 m3/h
|
||||
20-180m3/h
|
12-60 m3/h
|
||||
20-200m3/h
|
15s,25s,32s,50s,65s
|
||||
LZB-150
|
555
|
定做最大可做到220m3/h
|
可改法兰连接
|
||
法兰带导杆
|
|
|
|
二、塑料管浮子流量计安装
1、流量计必须安装在垂直位置上(流量计中心线与铅垂直线的夹角不超过5℃)并有正确的支承,以防止任何应力传入。对于新安装管路,在安装流量计之前应将管道冲洗干净。
2、为便于在使用过程中更换零件,流量计安装时,它的周围应留有足够的空间。
3、为检修、修理、更换流量计和清洗管路的需要,推荐流量计安装时按图4所示的方式安装旁路管。
4、流量计上游应安装阀门,在下游5~10倍公称通径处安装调节流量的节流阀。
5、为防止管路中的回流或有水锤作用损坏流量计,可在流量计下流阀门之后安装单向逆止阀。
6、如被测流体含有较大颗粒杂质或脏物,应根据需要在流量计上游安装过滤器。图4 旁路管安装示意图
7、如被测流体是脉动流,造成浮子波动不能正确测量时,流量计上游的阀门应全开。并设置适当尺寸的缓冲器和定值器,以防止由于压力过分下降而能引起的回流和消除脉动冲。
三、塑料管浮子流量计使用
1、流量计使用时,应缓慢开启上游阀门至全开,然后用流量计下游的调节阀调节流量。流量计停止工作时,应先缓慢关闭流量计上游阀门,然后再关闭流量计的流量调节阀。
2、使用时应避免被测流体压力的急骤变化。
3、按图1所示的浮子读数边读边数。
4、浮子的工作直径(读数边)如有损伤,应重新标定。
5、使用中的流量计,如发现有渗漏,应均匀地紧固压盖螺栓(或压紧帽),此时应避免过分紧固而夹碎锥管。若上述方法不行,一般是密封填料失效,应更换锥管密封填料。
6、更换密封填料、锥管或浮子时,先拆下外罩,小心均匀地松开压螺栓(或压紧帽),然后拆下支承板和上、下基座。在上述过程中,切勿用力过大,同时在拆下基座时要托住锥管,以免碰损锥管及浮子。
7、如锥管和浮子沾污、应及时清洗。
8、被测流体的状态(密度、温度、压力、粘度等)与流量计分度状态不同时,必须对示值进行修正。